FRFirst Run Notes
Issue 26  /  first run & acceptance2026-11-24
03 / 08BaselineIssue 26

A vibration baseline is taken once and pays for itself every year

The reading that matters is the one taken before anything failed, at a known rate and a known load. It cannot be reconstructed afterwards.

The reading that matters is the one taken before anything failed, at a known rate
03 · Baseline · First Run Notes

Why a baseline cannot be reconstructed later

Condition monitoring is usually sold as a sensor and a subscription. The part that decides whether it works is older and cheaper: a reference measurement taken while the machine is healthy, at a stated operating point, with a stated method. Without it, every later reading is a number with no direction.

The reference cannot be bought later. Once a bearing has begun to degrade, the machine's present spectrum is a mixture of the original signature and the fault, and there is no arithmetic that separates them. The only clean measurement is the one taken before anything was wrong.

This is why the baseline belongs to commissioning rather than to maintenance. In the fourth stage of a commissioning run the machine is at rate, at load, at temperature, and known to be correct. That combination occurs once in the machine's life, and it occurs on a day when nobody is thinking about the future.

The cost of taking it is an hour and a notebook. The cost of not taking it is that the first serious fault arrives with no reference, and the decision becomes whether to stop the line on a number nobody can interpret.

What a vibration number actually contains

A single overall vibration value, expressed as velocity in millimetres per second root mean square, is an aggregate. It adds the contribution of every frequency between the sensor's lower and upper limit, weighted by a standard curve, and reports one figure.

Aggregates are useful for alarms and useless for diagnosis. Two machines with the same overall value can have completely different faults: one has an unbalanced fan, the other has a gear tooth wearing. The aggregate sees both as energy and does not care where it came from.

The information is in the distribution, which is why the baseline should be a spectrum and not a number. A spectrum taken at commissioning, stored as a file with its settings, is the reference that makes every later spectrum comparable. A number is a summary that cannot be expanded.

Practical compromise: store both. The overall value is what an operator can check weekly without training. The spectrum is what an engineer reads when the overall value moves.

The three axes and the mount

Vibration is directional, and a fault is often visible on one axis and invisible on another. A misaligned coupling shows strongly in the radial direction and weakly in axial. An angular contact bearing fault can appear axially first. Measuring one axis is measuring a third of the machine.

The mount matters as much as the axis. A sensor held against a painted cover with a hand is measuring the cover. The same sensor on a stud, on bare metal, near the bearing housing, is measuring the machine. The difference between those two readings can exceed the fault being looked for.

For a baseline that will be repeated, the mount must be repeatable: the same location, marked with a punch or a small plate, the same adaptor, the same orientation. Photographs of the sensor in position, taken at commissioning, are the cheapest way to make next year's reading comparable.

Accelerometers also have a frequency range that ends somewhere, and the useful part of a bearing signature lives near the top of it. A sensor that is adequate for balance measurements and mounted on a flexible panel will report a clean machine right up to the week it seizes.

Rate and load belong on the sheet

Vibration amplitude scales with speed and with load, so a reading without them is a reading of an unknown operating point. The same bearing at fifty percent rate and at rated rate produces two different spectra, both correct, neither comparable.

The discipline is to record the operating point as part of the measurement: rate, load, product variant, and the temperature at the time. Then the baseline is not a spectrum but a small family of spectra, one per operating point that the machine actually uses.

Most machines run at two or three points that matter, not at a continuum. Recording a baseline at each of them takes an afternoon and covers the states in which a fault will actually be noticed.

The transient states, acceleration and deceleration, are deliberately excluded. They are informative in expert hands and they are not repeatable enough to trend, and a baseline's whole value is repeatability.

Reading the spectrum instead of the number

A spectrum is a plot of amplitude against frequency, and reading it is a matter of recognising families of peaks rather than memorising values. The first thing to identify is the shaft speed and its harmonics, because almost every mechanical fault modulates one of them.

The second is the set of bearing frequencies, which are fixed by geometry and are not harmonics of shaft speed. They are calculated from the bearing's dimensions and its contact angle, and they are what make a bearing fault distinguishable from an imbalance.

The third is the noise floor, which is the broadband level between the peaks. A rising floor with unchanged peaks is a different story from rising peaks with an unchanged floor, and the first story is usually lubrication or clearance rather than a discrete defect.

A baseline spectrum is therefore kept as a picture with the frequency axis labelled. A spectrum without a labelled axis is a shape, and a shape cannot be compared across a change of analyser or a change of setting.

The frequencies that announce specific faults

Shaft speed once per revolution, with a strong radial component and little axial content, is the classic signature of imbalance. It grows with the square of speed, so it is loudest at the highest rate the machine uses, which is also the point where it is least tolerable.

Twice per revolution, strong in radial and often accompanied by axial content, points to misalignment or to a coupling problem. It is frequently accompanied by a loosened bearing housing, which produces a family of harmonics rather than a single peak.

High frequency energy in a band well above the shaft harmonics, appearing as a raised carpet rather than as discrete peaks, is the earliest evidence of a bearing in trouble. At that stage the defect is too small to excite its own frequencies, and the energy is carried by resonance instead.

Discrete peaks at the bearing's calculated defect frequencies, with sidebands spaced at shaft speed, mean the defect has grown enough to modulate. That is a later stage, and the spacing of the sidebands tells you which element is involved.

Trend needs a repeatable method, not a good instrument

A trend is a sequence of comparable numbers. Comparability comes from method, and method is cheaper than instrumentation. The same location, the same mount, the same analyser settings, the same operating point, the same person if possible.

Projects that buy an expensive analyser and change the setup each time produce a folder of interesting pictures and no trend. Projects with a cheap meter used identically every month produce a line that shows a bearing dying three weeks before it does.

The settings that must be fixed are fewer than they look: frequency range, resolution, windowing, averaging, and the units of the amplitude axis. Four settings, written on the sheet, make a decade of readings comparable.

The person matters less than the procedure, but the person matters some. Two technicians with different hands produce a scatter of a few percent, which is acceptable for trend and unacceptable for a pass or fail on a tight limit.

Alarm bands set from data, not from a table

Generic alarm tables are the most common reason condition monitoring produces false alarms and then gets ignored. A table written for one class of machine applied to another produces a band that is either permanently exceeded or never reached.

The defensible method is to set the band from the machine's own baseline and its own history. A common rule is that a change of a stated multiple of the baseline's variability, sustained over two or three readings, is worth a look, and a larger multiple is worth a stop.

The variability is the key figure, and it requires several readings at the same operating point to establish. A baseline of one reading cannot give a variability, and a band set without variability will be set by guesswork.

The bands should also differ by operating point, because a machine's normal vibration at low rate is not its normal vibration at rate. One band for all conditions is a band that alarms every time the machine speeds up.

The annual arithmetic of a baseline

The value of a baseline is not diagnostic elegance, it is the avoidance of a small number of very expensive events. A bearing that is replaced on a planned stop costs a bearing and a few hours. The same bearing that seizes costs a housing, a shaft, a production week and sometimes a fire.

The arithmetic usually presented is that a monitored machine pays for its instrumentation with one avoided failure. That arithmetic is roughly right, and it understates the value because it ignores the second effect: a machine with a baseline can be run to its actual condition rather than to a calendar.

Running to condition also means not replacing healthy parts. The saving is real and it is usually larger than the avoided failure, because it recurs every service interval rather than once.

The condition for all of this is the reference measurement, taken at the one moment in the machine's life when it is known to be correct. That moment is commissioning, and it lasts a few days.

The frequency families and the trend method summarised here are treated at more length in vibration based predictive maintenance, which is also where the alarm bands for a baseline are set.

Checkpoints12
  • A baseline spectrum is stored for every operating point the machine actually uses.
  • The overall velocity value is stored alongside the spectrum, for weekly operator checks.
  • Sensor locations are marked physically and photographed for the record.
  • Mount is on bare metal near the bearing housing, not on a cover or a panel.
  • The sensor's frequency range is adequate for the bearing defect frequencies involved.
  • Rate, load, product variant and temperature are recorded with every reading.
  • Frequency range, resolution, window, averaging and amplitude units are fixed in writing.
  • Radial and axial directions are both measured, at every marked location.
  • The shaft speed and its harmonics are identified on the baseline spectrum.
  • Bearing defect frequencies are calculated from geometry and noted on the sheet.
  • Alarm bands are set from the baseline's own variability, not from a generic table.