A bearing tells you it is failing long before it tells you it has failed
The signature moves through four stages, and each stage gives a different amount of time to act.

Four stages between first evidence and seizure
A rolling bearing does not fail at a moment, it fails over an interval, and the interval is usually long enough to be used. What changes across the interval is not the amount of damage but the way the damage announces itself, and each way of announcing corresponds to a different amount of remaining time.
The four stages are conventionally described by the frequency band in which the energy appears. First, ultrasonic energy that is above the audible range. Second, the bearing's own defect frequencies appearing as discrete peaks. Third, harmonics and sidebands as the defect modulates. Fourth, broadband noise as the geometry collapses.
The time between stage one and stage four varies enormously with load, speed, lubrication and size. It can be months on a slow conveyor and hours on a high speed spindle. The stages are a sequence, not a schedule, and the schedule has to be learned per machine.
The practical point is that stage one is detectable with inexpensive equipment and stage four is detectable by anyone in the room. The value of a monitoring programme is almost entirely in the earlier half of the sequence.
Stage one: the frequencies above the noise
Before a defect is large enough to strike its own resonance, it shows as increased energy in the ultrasonic band, typically above twenty kilohertz. At that stage a conventional velocity spectrum can look completely normal, which is why a clean spectrum is not a clean bearing.
The measurement that catches this is either an ultrasonic detector or an accelerometer with sufficient bandwidth and a high pass filter. Both report a rise in energy, and the rise is gradual and repeatable, which makes it trendable.
The interpretation is not specific. Ultrasonic energy rises for poor lubrication, for a marginal contact, and for a small spall alike. It tells you to look, and the later stages tell you what you are looking at.
The action at stage one is cheap and usually non-destructive: verify lubrication, verify alignment, verify that the housing is not fretting. A significant fraction of stage one findings are resolved by those three checks without any bearing being replaced.
Stage two: the defect frequency and its harmonics
Every bearing has four characteristic frequencies, derived from its geometry, its contact angle and the shaft speed. The outer race frequency, the inner race frequency, the rolling element frequency and the cage frequency. They are not multiples of shaft speed, which is exactly why they are identifiable.
When a defect on the outer race is struck repeatedly, energy appears at the outer race frequency and at its harmonics. Because the outer race is stationary, the amplitude is relatively stable and the series is clean. This is the most diagnosable of the four.
A defect on the inner race produces the same series at the inner race frequency, but with sidebands spaced at shaft speed, because the defect rotates in and out of the load zone. The presence of those sidebands is itself diagnostic, and their spacing confirms which element is at fault.
At stage two the bearing is still serviceable and the decision is scheduling rather than emergency. The honest advice is to plan the replacement into the next convenient stop, and to shorten the inspection interval in the meantime.
Stage three: the broadband floor rises
As the defect grows, the impacts excite resonances that are not the bearing's own, and the spectrum's floor rises across a wide band. Discrete peaks may still be present, but the space between them is no longer quiet.
This stage is where misdiagnosis is common. A rising floor with peaks that have merged looks like a general deterioration, and general deterioration is often treated as a symptom to be tolerated. In a bearing, a rising floor after a known defect series means the defect has spread.
The rate of change at stage three is the most useful number available. A floor that rose over six months is a slow event. A floor that rose over two weeks, on the same machine at the same load, is a bearing that has entered its final phase regardless of how it sounds.
The action at stage three is to set a date and prepare. Bearing, housing inspection, shaft check, and the alignment tools. Preparing them while the machine still runs is the difference between a planned stop and a long one.
Stage four: the impact pattern and the last window
At stage four the impacts become audible and the spectrum becomes a broadband noise floor with little structure. The bearing may still turn, which is the deceptive part, and it may turn for days under light load.
The remaining window at this stage is short and unpredictable, and it is measured in hours to weeks rather than months. The failure mode also changes character: rather than a gradual loss of accuracy, the risk becomes a seizure, a broken cage or a destroyed housing.
Temperature is the practical signal at this stage, because friction energy has to go somewhere. A housing that runs ten degrees hotter than its baseline at the same load is a bearing that is about to stop being a bearing. This is why a simple infrared reading is worth taking weekly on critical machines.
The decision at stage four is not technical. Run to failure is a legitimate choice on a machine whose failure is contained and cheap. It is not legitimate on a machine whose failure takes a housing with it, and that judgement belongs in the maintenance plan rather than in the moment.
What the mounting does to the signature
A bearing inside a housing, inside a frame, inside a guard is a bearing whose signature passes through several interfaces before it reaches a sensor. Every interface attenuates high frequencies more than low ones, which is why bearing evidence is easiest to see close to the bearing.
Mounting the sensor on the housing near the bearing's load zone gives the cleanest high frequency content. Mounting it on the frame gives a smoothed version that may hide stage one and stage two entirely while showing stage four clearly.
The practical consequence is that the mount position is part of the diagnosis, not an inconvenience. Two readings from two positions are two different measurements, and only one of them can be compared with a baseline taken at the other position.
Where a permanent sensor is not possible, a marked stud on the housing is the next best thing. A stud costs a few minutes to install at commissioning and makes every future reading comparable, which is the entire requirement.
Selection is a life calculation, not a catalogue page
A bearing's catalogue lists a basic dynamic load rating and a basic static load rating, and neither of them is a life. Life comes from the rating combined with the actual load, the actual speed and a set of factors for lubrication, contamination and reliability.
The calculation's output is an L10 life, which is the life reached by ninety percent of a population under those conditions. The number that matters for a maintenance plan is not the average but the tenth percentile, and the tenth percentile is what L10 already is.
The factors that move the answer most are contamination and lubrication, and neither is in the catalogue. A bearing selected on load alone and installed in a dirty environment has a life a fraction of the calculated one, and the failure will be attributed to the bearing's quality.
Selection therefore starts with the environment and the maintenance regime, and only then consults the catalogue. A slightly larger bearing with better sealing frequently outlives a theoretically optimal one that is under-protected.
Replacement decisions and the cost of being early
Replacing a bearing at stage one costs a bearing and a stop, and buys very little, because stage one is often reversible. Replacing at stage two costs the same and buys certainty. Replacing at stage four costs a bearing, a stop, and whatever the failure takes with it.
The economically correct point is usually between stage two and stage three, and it is determined by the machine's criticality rather than by the bearing. On a redundant pump, waiting is rational. On a single machine feeding a line, waiting is a bet against the line's output.
Being early has a cost that is rarely counted: the disturbance of a replacement itself. Every bearing replacement is an opportunity to introduce a new fault, through a damaged seal, a misaligned housing, or an incorrect preload. A replacement that was not needed is a risk taken for no return.
A defensible policy states the action per stage per machine class, in advance, and in writing. The value of writing it in advance is that the decision is made by people who are not under pressure at three in the morning.
The record that makes the next failure shorter
Each bearing failure produces information that is worth more than the bearing's cost, provided it is written down while the evidence is open. The information is: the stage at which it was first detected, the interval to each later stage, the mounting position, the load and the speed, and what the surfaces looked like when opened.
The surfaces are the most valuable and the most perishable. A spall's position on the race, the pattern of the damage, the colour of the grease and the presence of water all point to a cause, and all are lost the moment the bearing is thrown in a bin.
Photographs taken before cleaning are the cheapest form of this record. Four images, the outer race, the inner race, the rolling elements and the grease, cost a minute and answer most of the questions that arise later.
A plant with a file of these records stops arguing about bearing quality and starts correcting the conditions that produce the failures. That is the point at which condition monitoring stops being a subscription and becomes an asset.
The four stage sequence and the mounting argument above follow the same logic as bearing failure analysis and bearing selection, which covers the selection side of the same decision.
- The four characteristic frequencies are calculated and recorded per bearing per speed.
- Ultrasonic or high frequency energy is measured, not only velocity in the audible band.
- The sensor is mounted close to the bearing's load zone, on bare metal.
- A marked stud position is established at commissioning for repeatable readings.
- The rate of change of the broadband floor is recorded, not only its absolute level.
- Housing temperature is read weekly on critical machines, against a baseline.
- Catalogue life is recalculated with lubrication and contamination factors.
- Sealing and environment are considered before bearing size is optimised.
- The action per stage per machine class is written in advance.
- The stage at which the fault was first detected is recorded for every failure.
- Surfaces are photographed before cleaning, including the grease condition.
- Replacement is treated as a risk event, with alignment and preload checked after.